Scientia Iranica

Scientia Iranica

Comparing Shape and Image Reconstruction in Electrical Capacitance Tomography

Author
School of Material Science,The University of Manchester
Abstract
Electrical Capacitance Tomography (ECT) is an imaging technique that maps the electrical permittivity contrast of the object. This paper studies an image and a shape reconstruction method for ECT. For image reconstruction, a regularized Gauss-Newton method has been implemented, based on the inverse finite element technique. For shape reconstruction, a narrowband level set method has been developed. Using experimental ECT data, a comparative study of these two techniques is the main objective of this paper.

Volume 13, Issue 3 - Serial Number 3
Transactions on Civil Engineering (A)
July 2006

  • Receive Date 26 September 2006
  • Accept Date 30 September 2006