In this study the effect of parametric variatıon of the pole-arc offset distance on the performance of a permanent-magnet synchronous generator (PMSG) used in wind energy applications has been investigated. Fourier analyses of the voltage wave-shapes that are obtained by the parametric variation of the pole-arc offset value have been made. The THD is determined for each voltage wave-shape. As a result of optimization study the efficiency and the output power have been kept approximately constant. The THD of the output voltage has been decreased
Dalcalı, A. and AKBABA, M. (2017). Optimum Pole Arc Offset in Permanent Magnet Synchronous Generators for Obtaining Least Voltage Harmonics. Scientia Iranica, 24(6), 3223-3230. doi: 10.24200/sci.2017.4357
MLA
Dalcalı, A. , and AKBABA, M. . "Optimum Pole Arc Offset in Permanent Magnet Synchronous Generators for Obtaining Least Voltage Harmonics", Scientia Iranica, 24, 6, 2017, 3223-3230. doi: 10.24200/sci.2017.4357
HARVARD
Dalcalı, A., AKBABA, M. (2017). 'Optimum Pole Arc Offset in Permanent Magnet Synchronous Generators for Obtaining Least Voltage Harmonics', Scientia Iranica, 24(6), pp. 3223-3230. doi: 10.24200/sci.2017.4357
CHICAGO
A. Dalcalı and M. AKBABA, "Optimum Pole Arc Offset in Permanent Magnet Synchronous Generators for Obtaining Least Voltage Harmonics," Scientia Iranica, 24 6 (2017): 3223-3230, doi: 10.24200/sci.2017.4357
VANCOUVER
Dalcalı, A., AKBABA, M. Optimum Pole Arc Offset in Permanent Magnet Synchronous Generators for Obtaining Least Voltage Harmonics. Scientia Iranica, 2017; 24(6): 3223-3230. doi: 10.24200/sci.2017.4357