Submicron particle deposition in pulmonary alveoli during cyclic breathing

Document Type : Article

Authors

1 School of Mechanical Engineering, Sharif University of Technology, Tehran, Iran.

2 School of Mechanical Engineering, Sharif University of Technology, Tehran, Iran

3 Department of Mechanical and Aeronautical Engineering, Clarkson University, Potsdam, New York, USA.

Abstract

The prediction of deposition eciency of submicron particles in the pulmonary alveoli has received special attention due to its importance for drug delivery systems and for assessing air pollutants health risks. In this work, the pulmonary alveoli of a healthy human are idealized by a three-dimensional honeycomb-like con guration and a  fluid-structure interaction analysis is performed. In contrast to previous works in which the inlet
ow rate is prede ned, in this model, a negative pressure is imposed on the outside surface of the alveolus which causes air to  flow in and out of the alveolus. The resulting flow patterns con rmed that there was no circulation in the terminal alveolus. The predicted alveolar air flow was used to calculate the trajectories of submicron particles using the Lagrangian approach. Our ndings suggest that an accurate simulation requires including at least ten breathing cycles, considering a parabolic radial distribution of injected particles and
continuous injection. The presented results show high deposition eciency for submicron sizes in the alveolar region if these particles can reach the alveolar region. Therefore, the vesicles technology in which particle agglomerates would be released after the vesicle reaching the alveoli is suggested for targeted drug delivery to the alveolar region.

Keywords

Main Subjects


Volume 24, Issue 4
Transactions on Mechanical Engineering (B)
July and August 2017
Pages 1975-1984