<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Sharif University of Technology</PublisherName>
				<JournalTitle>Scientia Iranica</JournalTitle>
				<Issn>1026-3098</Issn>
				<Volume></Volume>
				<Issue>Articles in Press</Issue>
				<PubDate PubStatus="epublish">
					<Year>2024</Year>
					<Month>11</Month>
					<Day>18</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Experimental Assessment of a Continuously Operating Solar Vapour Adsorption Cooling System Operated with Composite adsorbent/ethanol as working pair</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage></FirstPage>
			<LastPage></LastPage>
			<ELocationID EIdType="pii">23742</ELocationID>
			
<ELocationID EIdType="doi">10.24200/sci.2024.63887.8644</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>V.</FirstName>
					<LastName>Baiju</LastName>
<Affiliation>Energy Research Lab, Department of Mechanical Engineering, TKM College of Engineering, Kollam, 
Kerala-691005, India</Affiliation>
<Identifier Source="ORCID">0000-0003-1967-1245</Identifier>

</Author>
<Author>
					<FirstName>A.</FirstName>
					<LastName>Asif Sha</LastName>
<Affiliation>TKM College of Engineering, Kollam, Kerala-691005 and IHRD College of Engineering, Kottarakkara, Kollam, Kerala-691531, India</Affiliation>
<Identifier Source="ORCID">0000-0003-1967-1245</Identifier>

</Author>
<Author>
					<FirstName>S.</FirstName>
					<LastName>Shajan</LastName>
<Affiliation>SCT College of Engineering, Thiruvananthapuram, Kerala-695018, India</Affiliation>
<Identifier Source="ORCID">0000-0003-1967-1245</Identifier>

</Author>
<Author>
					<FirstName>S. B.</FirstName>
					<LastName>Vishnu</LastName>
<Affiliation>Energy Research Lab, Department of Mechanical Engineering, TKM College of Engineering, Kollam, 
Kerala-691005, India</Affiliation>

</Author>
<Author>
					<FirstName>Shaleena</FirstName>
					<LastName>Manafuddin</LastName>
<Affiliation>Department of Electrical and Electronics Engineering, TKM College of Engineering, Kerala-691005, India</Affiliation>

</Author>
<Author>
					<FirstName>V. S.</FirstName>
					<LastName>Parvathi</LastName>
<Affiliation>Department of Electronics and Communication Engineering, LBS Institute for Women, Kerala-695012, India</Affiliation>

</Author>
<Author>
					<FirstName>Rizwan</FirstName>
					<LastName>Rasheed</LastName>
<Affiliation>Energy Research Lab, Department of Mechanical Engineering, TKM College of Engineering, Kollam, 
Kerala-691005, India</Affiliation>

</Author>
<Author>
					<FirstName>Ajmi</FirstName>
					<LastName>Midhlaj</LastName>
<Affiliation>- Energy Research Lab, Department of Mechanical Engineering, TKM College of Engineering, Kollam, 
Kerala-691005, India
- Research Scholar, APJ Abdul Kalam Technological University, Kerala-695016, India</Affiliation>

</Author>
<Author>
					<FirstName>Ashna</FirstName>
					<LastName>Maria Martin</LastName>
<Affiliation>- Energy Research Lab, Department of Mechanical Engineering, TKM College of Engineering, Kollam, 
Kerala-691005, India
- Research Scholar, APJ Abdul Kalam Technological University, Kerala-695016, India</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>01</Month>
					<Day>07</Day>
				</PubDate>
			</History>
		    <Abstract>Adsorption cooling is a tried-and-true efficient heat conversion technology that can substantially reduce pollution while increasing energy efficiency. The conventional single-bed adsorption system for cooling purposes has a low efficiency because it is prone to intermittent cooling. Moreover, the adsorbent-adsorbate pair of typical adsorption system for cooling contributes significantly to its inefficiency. This study suggests a composite adsorbent that is synthesized by activated carbon as the parent element, with expanded natural graphite powder and metal-organic framework as secondary elements. In the composite, polyvinylpyrrolidone is the binder. The design, development, and performance study of the cooling system operated with activated carbon-ethanol as well as the composite adsorbent-ethanol has been examined. For experimental purposes, a two-bed adsorption system has been designed, operating with solar energy and a chilling capacity of 600 W. The performance of the system using the suggested working pair has been experimentally evaluated. It is found that coefficient of performance of the system is 0.54 at a desorption temperature 88°C. It has been observed that the COP of the system increases by 20.69% compared to the adsorption system that utilizes activated carbon-ethanol. The introduction of the composite adsorbent-adsorbate operating pair could greatly enhance the performance of adsorption cooling systems.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">adsorbate</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">adsorbent</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Cooling</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">energy</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">solar</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://scientiairanica.sharif.edu/article_23742_2d1bafe55b0b49961617e5b71cbb1292.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
