<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Sharif University of Technology</PublisherName>
				<JournalTitle>Scientia Iranica</JournalTitle>
				<Issn>1026-3098</Issn>
				<Volume>26</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2019</Year>
					<Month>12</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Fast and clean dielectric barrier discharge plasma functionalization of carbon nanotubes decorated by electrodeposited nickel oxide: Application to glucose biosensors</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>3896</FirstPage>
			<LastPage>3904</LastPage>
			<ELocationID EIdType="pii">21441</ELocationID>
			
<ELocationID EIdType="doi">10.24200/sci.2019.51666.2302</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>A.A.</FirstName>
					<LastName>Khodadadi</LastName>
<Affiliation>Catalysis and Nanostructured Laboratory, School of Chemical Engineering, University of Tehran, Tehran, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-1431-5340</Identifier>

</Author>
<Author>
					<FirstName>Y.</FirstName>
					<LastName>Mortazavi</LastName>
<Affiliation>Nanoelectronics Centre of Excellence, University of Tehran, Tehran, P.O. Box 11365-4563, Iran.</Affiliation>
<Identifier Source="ORCID">0000-0002-7581-5023</Identifier>

</Author>
<Author>
					<FirstName>M.</FirstName>
					<LastName>Vesali-Naseh</LastName>
<Affiliation>Department of Chemical Engineering, Hamedan University of Technology, Hamedan, 65155, Iran</Affiliation>
<Identifier Source="ORCID">0000-0001-6117-6083</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>09</Month>
					<Day>18</Day>
				</PubDate>
			</History>
		    <Abstract>Multi-walled carbon nanotubes (MWCNTs) were functionalized using a dielectric barrier discharge plasma in presence of H2O-saturated air at 70˚C and atmospheric pressure. The functionalized MWCNTs (F-CNTs) were decorated with electrochemically deposited 10 nm NiO nanoparticles, followed by immobilization of glucose oxidase (GOx) and the modified electrode was utilized for electrochemical detection of glucose. TEM, FE-SEM, TPD and XPS techniques were used to characterize the NiO/F-CNTs samples. The maximum amount of oxygenated functional groups such as carbonyl, hydroxyl and carboxylic groups was formed at the plasma exposure time of 4 min. The optimum chronoamperometric deposition time of NiO was 3 min. The presence of GOx on the NiO/F-CNTs electrode displayed a quasi-reversible and surface-controlled redox wave around −0.52 V with a peak to peak separation of 0.05 V. The GOx/NiO/F-CNTs electrode showed a linear performance in the range of 0.2-3.8 mM glucose with detection limit of 93.0 µM and sensitivity of 2.16 µA.mM−1.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Plasma</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Functional</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">carbon nanotubes</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Nickel</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Biosensor</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://scientiairanica.sharif.edu/article_21441_bfb1e233aabeb71729f501798f85f4f4.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
